{
  "company": {
    "name": "Lumitech Tertiaire SAS",
    "siret": "84291056700024",
    "sector": "ESN — Services numériques B2B",
    "effectif": 280,
    "caM_EUR": 38,
    "bilanM_EUR": 28,
    "surfaceTertiaireM2": 8350,
    "contact": "Camille Verneuil — Directrice Patrimoine & RSE",
    "iso50001": false
  },
  "batiments": [
    {
      "id": "BAT-PARIS-S",
      "nom": "Siège social — Tour Lumière",
      "adresse": "12 quai de Bercy",
      "ville": "75012 Paris",
      "surfaceM2": 4500,
      "categorie": "BUREAUX_SERVICES_PUBLICS",
      "sousCategories": [
        {
          "code": "BUREAUX_SERVICES_PUBLICS",
          "surfaceM2": 4100
        },
        {
          "code": "RESTAURATION",
          "surfaceM2": 400
        }
      ],
      "anneeConstruction": 1998,
      "anneeRef": 2019,
      "consoRefKWhM2An": 220,
      "zoneClimatique": "H1a",
      "contractElec": "HTA",
      "arenh": true
    },
    {
      "id": "BAT-LYON-A",
      "nom": "Agence Lyon Part-Dieu",
      "adresse": "45 cours Lafayette",
      "ville": "69003 Lyon",
      "surfaceM2": 1800,
      "categorie": "BUREAUX_SERVICES_PUBLICS",
      "sousCategories": [
        {
          "code": "BUREAUX_SERVICES_PUBLICS",
          "surfaceM2": 1800
        }
      ],
      "anneeConstruction": 2008,
      "anneeRef": 2019,
      "consoRefKWhM2An": 195,
      "zoneClimatique": "H1c",
      "contractElec": "BT_PLUS",
      "arenh": false
    },
    {
      "id": "BAT-BDX-A",
      "nom": "Agence Bordeaux Mériadeck",
      "adresse": "8 rue Robert Lateulade",
      "ville": "33000 Bordeaux",
      "surfaceM2": 1200,
      "categorie": "BUREAUX_SERVICES_PUBLICS",
      "sousCategories": [
        {
          "code": "BUREAUX_SERVICES_PUBLICS",
          "surfaceM2": 1200
        }
      ],
      "anneeConstruction": 1985,
      "anneeRef": 2019,
      "consoRefKWhM2An": 305,
      "zoneClimatique": "H2c",
      "contractElec": "BT_PLUS",
      "arenh": false
    },
    {
      "id": "BAT-PARIS-DC",
      "nom": "Data center Aubervilliers",
      "adresse": "21 rue des Fillettes",
      "ville": "93300 Aubervilliers",
      "surfaceM2": 850,
      "categorie": "DATA_CENTER",
      "sousCategories": [
        {
          "code": "DATA_CENTER",
          "surfaceM2": 850
        }
      ],
      "anneeConstruction": 2015,
      "anneeRef": 2019,
      "consoRefKWhM2An": 1450,
      "zoneClimatique": "H1a",
      "contractElec": "HTA",
      "arenh": true
    }
  ],
  "conso": [
    {
      "id": "CSO-00001",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2024-06",
      "energies": {
        "ELEC_HP": 21348,
        "ELEC_HC": 13084,
        "GAZ": 3251
      },
      "factureEur": 4522,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00002",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2024-07",
      "energies": {
        "ELEC_HP": 26739,
        "ELEC_HC": 16389,
        "GAZ": 1593
      },
      "factureEur": 5367,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00003",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2024-08",
      "energies": {
        "ELEC_HP": 27898,
        "ELEC_HC": 17099,
        "GAZ": 1686
      },
      "factureEur": 5602,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00004",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2024-09",
      "energies": {
        "ELEC_HP": 20933,
        "ELEC_HC": 12830,
        "GAZ": 6784
      },
      "factureEur": 4866,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00005",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2024-10",
      "energies": {
        "ELEC_HP": 21259,
        "ELEC_HC": 13030,
        "GAZ": 29907
      },
      "factureEur": 7704,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00006",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2024-11",
      "energies": {
        "ELEC_HP": 22114,
        "ELEC_HC": 13553,
        "GAZ": 52959
      },
      "factureEur": 10635,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00007",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2024-12",
      "energies": {
        "ELEC_HP": 25506,
        "ELEC_HC": 15633,
        "GAZ": 66688
      },
      "factureEur": 12939,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00008",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-01",
      "energies": {
        "ELEC_HP": 25028,
        "ELEC_HC": 15340,
        "GAZ": 63110
      },
      "factureEur": 12417,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00009",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-02",
      "energies": {
        "ELEC_HP": 23442,
        "ELEC_HC": 14368,
        "GAZ": 58334
      },
      "factureEur": 11537,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00010",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-03",
      "energies": {
        "ELEC_HP": 20636,
        "ELEC_HC": 12648,
        "GAZ": 48306
      },
      "factureEur": 9791,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00011",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-04",
      "energies": {
        "ELEC_HP": 20316,
        "ELEC_HC": 12452,
        "GAZ": 26997
      },
      "factureEur": 7172,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00012",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-05",
      "energies": {
        "ELEC_HP": 19839,
        "ELEC_HC": 12160,
        "GAZ": 10860
      },
      "factureEur": 5143,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00013",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-06",
      "energies": {
        "ELEC_HP": 21675,
        "ELEC_HC": 13284,
        "GAZ": 3345
      },
      "factureEur": 4596,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00014",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-07",
      "energies": {
        "ELEC_HP": 27032,
        "ELEC_HC": 16568,
        "GAZ": 1817
      },
      "factureEur": 5450,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00015",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-08",
      "energies": {
        "ELEC_HP": 26734,
        "ELEC_HC": 16386,
        "GAZ": 1739
      },
      "factureEur": 5383,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00016",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-09",
      "energies": {
        "ELEC_HP": 21186,
        "ELEC_HC": 12985,
        "GAZ": 6593
      },
      "factureEur": 4892,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00017",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-10",
      "energies": {
        "ELEC_HP": 21730,
        "ELEC_HC": 13318,
        "GAZ": 27782
      },
      "factureEur": 7540,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00018",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-11",
      "energies": {
        "ELEC_HP": 24144,
        "ELEC_HC": 14798,
        "GAZ": 47227
      },
      "factureEur": 10340,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00019",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2025-12",
      "energies": {
        "ELEC_HP": 23946,
        "ELEC_HC": 14676,
        "GAZ": 70827
      },
      "factureEur": 13134,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00020",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2026-01",
      "energies": {
        "ELEC_HP": 25857,
        "ELEC_HC": 15848,
        "GAZ": 65017
      },
      "factureEur": 12807,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00021",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2026-02",
      "energies": {
        "ELEC_HP": 23943,
        "ELEC_HC": 14675,
        "GAZ": 55425
      },
      "factureEur": 11285,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00022",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2026-03",
      "energies": {
        "ELEC_HP": 22701,
        "ELEC_HC": 13913,
        "GAZ": 48302
      },
      "factureEur": 10190,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00023",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2026-04",
      "energies": {
        "ELEC_HP": 18488,
        "ELEC_HC": 11331,
        "GAZ": 25775
      },
      "factureEur": 6671,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00024",
      "batimentId": "BAT-PARIS-S",
      "yyyymm": "2026-05",
      "energies": {
        "ELEC_HP": 18525,
        "ELEC_HC": 11354,
        "GAZ": 9542
      },
      "factureEur": 4731,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00025",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2024-06",
      "energies": {
        "ELEC_HP": 7589,
        "ELEC_HC": 4651,
        "GAZ": 1180
      },
      "factureEur": 1610,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00026",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2024-07",
      "energies": {
        "ELEC_HP": 9282,
        "ELEC_HC": 5689,
        "GAZ": 574
      },
      "factureEur": 1865,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00027",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2024-08",
      "energies": {
        "ELEC_HP": 8846,
        "ELEC_HC": 5422,
        "GAZ": 643
      },
      "factureEur": 1789,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00028",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2024-09",
      "energies": {
        "ELEC_HP": 7288,
        "ELEC_HC": 4467,
        "GAZ": 2564
      },
      "factureEur": 1718,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00029",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2024-10",
      "energies": {
        "ELEC_HP": 7089,
        "ELEC_HC": 4345,
        "GAZ": 9880
      },
      "factureEur": 2558,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00030",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2024-11",
      "energies": {
        "ELEC_HP": 8130,
        "ELEC_HC": 4983,
        "GAZ": 19059
      },
      "factureEur": 3861,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00031",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2024-12",
      "energies": {
        "ELEC_HP": 9403,
        "ELEC_HC": 5763,
        "GAZ": 23915
      },
      "factureEur": 4690,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00032",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-01",
      "energies": {
        "ELEC_HP": 8908,
        "ELEC_HC": 5460,
        "GAZ": 22638
      },
      "factureEur": 4441,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00033",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-02",
      "energies": {
        "ELEC_HP": 8068,
        "ELEC_HC": 4945,
        "GAZ": 19597
      },
      "factureEur": 3913,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00034",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-03",
      "energies": {
        "ELEC_HP": 7532,
        "ELEC_HC": 4616,
        "GAZ": 16120
      },
      "factureEur": 3392,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00035",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-04",
      "energies": {
        "ELEC_HP": 7225,
        "ELEC_HC": 4428,
        "GAZ": 9597
      },
      "factureEur": 2550,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00036",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-05",
      "energies": {
        "ELEC_HP": 7250,
        "ELEC_HC": 4443,
        "GAZ": 3700
      },
      "factureEur": 1847,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00037",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-06",
      "energies": {
        "ELEC_HP": 7751,
        "ELEC_HC": 4750,
        "GAZ": 1186
      },
      "factureEur": 1642,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00038",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-07",
      "energies": {
        "ELEC_HP": 9652,
        "ELEC_HC": 5915,
        "GAZ": 623
      },
      "factureEur": 1943,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00039",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-08",
      "energies": {
        "ELEC_HP": 9354,
        "ELEC_HC": 5733,
        "GAZ": 579
      },
      "factureEur": 1880,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00040",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-09",
      "energies": {
        "ELEC_HP": 7616,
        "ELEC_HC": 4668,
        "GAZ": 2513
      },
      "factureEur": 1776,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00041",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-10",
      "energies": {
        "ELEC_HP": 6992,
        "ELEC_HC": 4286,
        "GAZ": 10944
      },
      "factureEur": 2667,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00042",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-11",
      "energies": {
        "ELEC_HP": 8247,
        "ELEC_HC": 5055,
        "GAZ": 18968
      },
      "factureEur": 3872,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00043",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2025-12",
      "energies": {
        "ELEC_HP": 8887,
        "ELEC_HC": 5447,
        "GAZ": 24122
      },
      "factureEur": 4615,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00044",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2026-01",
      "energies": {
        "ELEC_HP": 8889,
        "ELEC_HC": 5448,
        "GAZ": 22649
      },
      "factureEur": 4438,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00045",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2026-02",
      "energies": {
        "ELEC_HP": 8096,
        "ELEC_HC": 4962,
        "GAZ": 21623
      },
      "factureEur": 4162,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00046",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2026-03",
      "energies": {
        "ELEC_HP": 7498,
        "ELEC_HC": 4595,
        "GAZ": 15953
      },
      "factureEur": 3366,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00047",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2026-04",
      "energies": {
        "ELEC_HP": 7314,
        "ELEC_HC": 4483,
        "GAZ": 9323
      },
      "factureEur": 2534,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00048",
      "batimentId": "BAT-LYON-A",
      "yyyymm": "2026-05",
      "energies": {
        "ELEC_HP": 7116,
        "ELEC_HC": 4362,
        "GAZ": 3703
      },
      "factureEur": 1822,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00049",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2024-06",
      "energies": {
        "ELEC_HP": 7898,
        "ELEC_HC": 4841,
        "GAZ": 1262
      },
      "factureEur": 1680,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00050",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2024-07",
      "energies": {
        "ELEC_HP": 9638,
        "ELEC_HC": 5907,
        "GAZ": 637
      },
      "factureEur": 1942,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00051",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2024-08",
      "energies": {
        "ELEC_HP": 9728,
        "ELEC_HC": 5962,
        "GAZ": 666
      },
      "factureEur": 1963,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00052",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2024-09",
      "energies": {
        "ELEC_HP": 7627,
        "ELEC_HC": 4674,
        "GAZ": 2551
      },
      "factureEur": 1782,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00053",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2024-10",
      "energies": {
        "ELEC_HP": 7294,
        "ELEC_HC": 4470,
        "GAZ": 10128
      },
      "factureEur": 2627,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00054",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2024-11",
      "energies": {
        "ELEC_HP": 8965,
        "ELEC_HC": 5495,
        "GAZ": 19359
      },
      "factureEur": 4058,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00055",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2024-12",
      "energies": {
        "ELEC_HP": 9715,
        "ELEC_HC": 5955,
        "GAZ": 25172
      },
      "factureEur": 4901,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00056",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-01",
      "energies": {
        "ELEC_HP": 9033,
        "ELEC_HC": 5537,
        "GAZ": 26047
      },
      "factureEur": 4874,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00057",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-02",
      "energies": {
        "ELEC_HP": 8859,
        "ELEC_HC": 5430,
        "GAZ": 20936
      },
      "factureEur": 4227,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00058",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-03",
      "energies": {
        "ELEC_HP": 7625,
        "ELEC_HC": 4673,
        "GAZ": 18883
      },
      "factureEur": 3742,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00059",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-04",
      "energies": {
        "ELEC_HP": 7380,
        "ELEC_HC": 4523,
        "GAZ": 10464
      },
      "factureEur": 2684,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00060",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-05",
      "energies": {
        "ELEC_HP": 7522,
        "ELEC_HC": 4610,
        "GAZ": 4069
      },
      "factureEur": 1944,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00061",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-06",
      "energies": {
        "ELEC_HP": 8492,
        "ELEC_HC": 5205,
        "GAZ": 1211
      },
      "factureEur": 1789,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00062",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-07",
      "energies": {
        "ELEC_HP": 10428,
        "ELEC_HC": 6391,
        "GAZ": 593
      },
      "factureEur": 2089,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00063",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-08",
      "energies": {
        "ELEC_HP": 9337,
        "ELEC_HC": 5723,
        "GAZ": 655
      },
      "factureEur": 1886,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00064",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-09",
      "energies": {
        "ELEC_HP": 8403,
        "ELEC_HC": 5150,
        "GAZ": 2659
      },
      "factureEur": 1945,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00065",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-10",
      "energies": {
        "ELEC_HP": 7631,
        "ELEC_HC": 4677,
        "GAZ": 10158
      },
      "factureEur": 2696,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00066",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-11",
      "energies": {
        "ELEC_HP": 8676,
        "ELEC_HC": 5318,
        "GAZ": 18239
      },
      "factureEur": 3868,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00067",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2025-12",
      "energies": {
        "ELEC_HP": 9030,
        "ELEC_HC": 5535,
        "GAZ": 25184
      },
      "factureEur": 4770,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00068",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2026-01",
      "energies": {
        "ELEC_HP": 9545,
        "ELEC_HC": 5850,
        "GAZ": 24054
      },
      "factureEur": 4734,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00069",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2026-02",
      "energies": {
        "ELEC_HP": 9373,
        "ELEC_HC": 5744,
        "GAZ": 21647
      },
      "factureEur": 4412,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00070",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2026-03",
      "energies": {
        "ELEC_HP": 11188,
        "ELEC_HC": 4729,
        "GAZ": 28557
      },
      "factureEur": 5337,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00071",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2026-04",
      "energies": {
        "ELEC_HP": 7239,
        "ELEC_HC": 4437,
        "GAZ": 10284
      },
      "factureEur": 2635,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00072",
      "batimentId": "BAT-BDX-A",
      "yyyymm": "2026-05",
      "energies": {
        "ELEC_HP": 6845,
        "ELEC_HC": 4195,
        "GAZ": 3783
      },
      "factureEur": 1779,
      "source": "Engie Pro"
    },
    {
      "id": "CSO-00073",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2024-06",
      "energies": {
        "ELEC_HP": 56350,
        "ELEC_HC": 34537
      },
      "factureEur": 10906,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00074",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2024-07",
      "energies": {
        "ELEC_HP": 58082,
        "ELEC_HC": 35599
      },
      "factureEur": 11242,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00075",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2024-08",
      "energies": {
        "ELEC_HP": 58836,
        "ELEC_HC": 36061
      },
      "factureEur": 11388,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00076",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2024-09",
      "energies": {
        "ELEC_HP": 55517,
        "ELEC_HC": 34026
      },
      "factureEur": 10745,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00077",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2024-10",
      "energies": {
        "ELEC_HP": 49610,
        "ELEC_HC": 30406
      },
      "factureEur": 9602,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00078",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2024-11",
      "energies": {
        "ELEC_HP": 50468,
        "ELEC_HC": 30932
      },
      "factureEur": 9768,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00079",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2024-12",
      "energies": {
        "ELEC_HP": 47070,
        "ELEC_HC": 28850
      },
      "factureEur": 9110,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00080",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-01",
      "energies": {
        "ELEC_HP": 47475,
        "ELEC_HC": 29098
      },
      "factureEur": 9189,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00081",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-02",
      "energies": {
        "ELEC_HP": 47437,
        "ELEC_HC": 29074
      },
      "factureEur": 9181,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00082",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-03",
      "energies": {
        "ELEC_HP": 49766,
        "ELEC_HC": 30502
      },
      "factureEur": 9632,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00083",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-04",
      "energies": {
        "ELEC_HP": 50402,
        "ELEC_HC": 30892
      },
      "factureEur": 9755,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00084",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-05",
      "energies": {
        "ELEC_HP": 51832,
        "ELEC_HC": 31768
      },
      "factureEur": 10032,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00085",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-06",
      "energies": {
        "ELEC_HP": 51205,
        "ELEC_HC": 31383
      },
      "factureEur": 9911,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00086",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-07",
      "energies": {
        "ELEC_HP": 60824,
        "ELEC_HC": 37279
      },
      "factureEur": 11772,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00087",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-08",
      "energies": {
        "ELEC_HP": 55559,
        "ELEC_HC": 34052
      },
      "factureEur": 10753,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00088",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-09",
      "energies": {
        "ELEC_HP": 56836,
        "ELEC_HC": 34835
      },
      "factureEur": 11001,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00089",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-10",
      "energies": {
        "ELEC_HP": 51149,
        "ELEC_HC": 31349
      },
      "factureEur": 9900,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00090",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-11",
      "energies": {
        "ELEC_HP": 50494,
        "ELEC_HC": 30948
      },
      "factureEur": 9773,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00091",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2025-12",
      "energies": {
        "ELEC_HP": 50708,
        "ELEC_HC": 31079
      },
      "factureEur": 9814,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00092",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2026-01",
      "energies": {
        "ELEC_HP": 47791,
        "ELEC_HC": 29291
      },
      "factureEur": 9250,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00093",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2026-02",
      "energies": {
        "ELEC_HP": 51309,
        "ELEC_HC": 31448
      },
      "factureEur": 9931,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00094",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2026-03",
      "energies": {
        "ELEC_HP": 46532,
        "ELEC_HC": 28520
      },
      "factureEur": 9006,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00095",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2026-04",
      "energies": {
        "ELEC_HP": 50350,
        "ELEC_HC": 30860
      },
      "factureEur": 9745,
      "source": "EDF Pro HTA"
    },
    {
      "id": "CSO-00096",
      "batimentId": "BAT-PARIS-DC",
      "yyyymm": "2026-05",
      "energies": {
        "ELEC_HP": 49118,
        "ELEC_HC": 30104
      },
      "factureEur": 9507,
      "source": "EDF Pro HTA"
    }
  ],
  "actions": [
    {
      "id": "ACT-001",
      "titre": "Isolation toit terrasse — Siège Paris",
      "description": "Isolation 1800 m² de toit terrasse, R ≥ 4,5. Cible -18 % conso chauffage siège.",
      "ficheCee": "BAT-EN-101",
      "batimentId": "BAT-PARIS-S",
      "investEur": 162000,
      "gainKwhAn": 145000,
      "gainEurAn": 16500,
      "ceeKWhCumac": 1656000,
      "ceeEur": 12420,
      "paybackAn": 9.1,
      "reductionPct": 0.04,
      "statut": "PLANIFIE",
      "echeance": "2027-03-30"
    },
    {
      "id": "ACT-002",
      "titre": "Remplacement LED — siège + agences",
      "description": "1200 luminaires LED ≥ 110 lm/W, détection présence intégrée.",
      "ficheCee": "BAT-EQ-127",
      "batimentId": "ALL",
      "investEur": 84000,
      "gainKwhAn": 88000,
      "gainEurAn": 24640,
      "ceeKWhCumac": 1740000,
      "ceeEur": 13050,
      "paybackAn": 2.9,
      "reductionPct": 0.025,
      "statut": "EN_COURS",
      "echeance": "2026-09-30"
    },
    {
      "id": "ACT-003",
      "titre": "Chaudière à condensation — Bordeaux",
      "description": "Remplacement chaudière fioul par chaudière gaz à condensation 180 kW.",
      "ficheCee": "BAT-TH-104",
      "batimentId": "BAT-BDX-A",
      "investEur": 48000,
      "gainKwhAn": 62000,
      "gainEurAn": 6800,
      "ceeKWhCumac": 3132000,
      "ceeEur": 23490,
      "paybackAn": 1.05,
      "reductionPct": 0.03,
      "statut": "PLANIFIE",
      "echeance": "2026-12-31"
    },
    {
      "id": "ACT-004",
      "titre": "GTB classe A — Tour Lumière",
      "description": "Déploiement GTB classe A NF EN ISO 52120-1 sur tout le siège.",
      "ficheCee": "BAT-TH-116",
      "batimentId": "BAT-PARIS-S",
      "investEur": 95000,
      "gainKwhAn": 220000,
      "gainEurAn": 24800,
      "ceeKWhCumac": 204750,
      "ceeEur": 1535,
      "paybackAn": 3.7,
      "reductionPct": 0.06,
      "statut": "PLANIFIE",
      "echeance": "2027-06-30"
    },
    {
      "id": "ACT-005",
      "titre": "Photovoltaïque ombrière parking Lyon",
      "description": "Ombrières photovoltaïques 220 kWc + autoconsommation collective.",
      "batimentId": "BAT-LYON-A",
      "investEur": 285000,
      "gainKwhAn": 245000,
      "gainEurAn": 38800,
      "ceeKWhCumac": 0,
      "ceeEur": 0,
      "paybackAn": 7.3,
      "reductionPct": 0.045,
      "statut": "PLANIFIE",
      "echeance": "2027-09-30"
    },
    {
      "id": "ACT-006",
      "titre": "Optimisation contrat TURPE + ARENH",
      "description": "Renégociation contrat HTA + optimisation puissance souscrite + sortie partielle ARENH.",
      "batimentId": "ALL",
      "investEur": 0,
      "gainKwhAn": 0,
      "gainEurAn": 18500,
      "ceeKWhCumac": 0,
      "ceeEur": 0,
      "paybackAn": 0,
      "reductionPct": 0,
      "statut": "EN_COURS",
      "echeance": "2026-08-31"
    },
    {
      "id": "ACT-007",
      "titre": "Free-cooling data center Aubervilliers",
      "description": "Système free-cooling air extérieur sur groupes froid 320 kW.",
      "ficheCee": "BAT-TH-158",
      "batimentId": "BAT-PARIS-DC",
      "investEur": 76000,
      "gainKwhAn": 145000,
      "gainEurAn": 18900,
      "ceeKWhCumac": 2176000,
      "ceeEur": 16320,
      "paybackAn": 3.15,
      "reductionPct": 0.018,
      "statut": "PLANIFIE",
      "echeance": "2027-04-30"
    },
    {
      "id": "ACT-008",
      "titre": "Sensibilisation occupants + sobriété",
      "description": "Programme animation interne : sobriété, éco-gestes, challenges inter-sites.",
      "batimentId": "ALL",
      "investEur": 12000,
      "gainKwhAn": 95000,
      "gainEurAn": 13200,
      "ceeKWhCumac": 0,
      "ceeEur": 0,
      "paybackAn": 0.9,
      "reductionPct": 0.018,
      "statut": "REALISE",
      "echeance": "2025-12-31"
    }
  ],
  "cee": [
    {
      "code": "BAT-EN-101",
      "params": {
        "surface": 1800,
        "zone": "H1a",
        "precarite": false
      },
      "kWhCumac": 1656000,
      "valeurEur": 12420,
      "date": "2026-04-02"
    },
    {
      "code": "BAT-EQ-127",
      "params": {
        "unites": 1200
      },
      "kWhCumac": 1740000,
      "valeurEur": 13050,
      "date": "2026-04-12"
    },
    {
      "code": "BAT-TH-104",
      "params": {
        "puissance": 180,
        "zone": "H2c",
        "precarite": false
      },
      "kWhCumac": 2479500,
      "valeurEur": 18596,
      "date": "2026-05-04"
    }
  ]
}